I am not exactly sure about how J & J coats the Cypher stent, but as far as I know, abluminal coating has only been mentioned in Bio-matrix, and the words of Prof Ostojic on the Cypher Stent is ' Coating - Entire Stent Surface'. For info only. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
bengster68
Master |
26-Aug-2008 22:05
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
Mr Investor, you mean JNJ is coating their Sirolimus drug around the entire Cypher stent surface including non-ablumenal surface? This is freaking stupid thing to do. Sirolimus (immuno-suppressent / anti-proliferative drug) will actually slow down / hinder endothelial regrowth on the non-ablumenal stent surface. Plus, the drug coating on non-ablumenal stent surface would have been partially washed away by the blood stream, thereby causing "systematic" drug effect on the entire body system which is definitely no good for the patient. Cannot believe JNJ stent engineers are so bird to coat Sirolimus drug on non-ablumenal stent surface! I think the OCT scan sure can see a huge endothelial regrowth difference between Biomatrix and Cypher. | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
|
|||||||||||||||||||||||
investor
Senior |
26-Aug-2008 21:30
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
To further elaborate on the 'Atrial Pacing' sub-study in the Nobori Core Clinical Trial. The study was done by Prof Miodrag Ostojic from Clinical Centre Serbia, Belgrade. He thinks that the reasons why the Biomatrix shows better recovery in Endothelial Functions than the Cypher stent are : 1) The Abluminal coating on the Bio-matrix stent versus the entire coating on the Cypher stent. This will allow the 'homing of endothelial progenitor cells to be LESS IMPAIRED' in the case of the bio-matrix. (In layman's language - it probably means that the inside of the vessel is not exposed to the biolimus drug, thereby allowing endothelial recovery. 2) Having a bio-degradable polymer in Bio-matrix versus a permanent polymer in Cypher. 3) Drug Release Profile. 4) Higher lipophilicity of Biolimus versus the Sirolimus. This presentation by Prof Ostojic was done during the Nobori Symposium held in the Europcr conference in May 2008. For info - Not a call to buy/sell. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
AK_Francis
Supreme |
26-Aug-2008 18:18
Yells: "Happy go lucky, cheers." |
||||||||||||||||||||||
x 0
x 0 Alert Admin |
In the mornning really tempting, at 0.53, good for avg. But kena the burger before, scare is the word. Stay sideline with this joker first, esp the current market is so volatile. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
jchongll
Member |
26-Aug-2008 16:01
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
looks very tempting... but scare false bull... anyone can see market depth? BB playing or juz retailers?? | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
|
|||||||||||||||||||||||
RoundStar
Member |
26-Aug-2008 16:00
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
now at 0.590. Chiong very fast | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
jackjames
Elite |
26-Aug-2008 15:51
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
hopefully tonight result is fantastic, then, tomorrow another round of bull run.. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
Centaur
Veteran |
26-Aug-2008 15:49
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
well, looks like cheonging up now.. Hopefully, this time round is not smoke only | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
|
|||||||||||||||||||||||
jackjames
Elite |
26-Aug-2008 14:46
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
i am thinking seriously of your comments below.... hope this time round is right... marketing time, baby.. if they don't show& sell well, fire the marketing manager.
|
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
jackjames
Elite |
26-Aug-2008 14:41
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
novena_33, I only know biosensor always give us surprises... that's it .. full stop, ha ha.. | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
novena_33
Veteran |
26-Aug-2008 14:33
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
seem like is having some impact on the price.....
|
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
RoundStar
Member |
26-Aug-2008 13:56
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
http://info.sgx.com/webcoranncatth.nsf/VwAttachments/Att_1CF1E0AC0F2A3D57482574B10019415B/$file/LEADERS_RELEASE_Announcement.pdf?openelement | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
|
|||||||||||||||||||||||
trader88.sg
Veteran |
26-Aug-2008 11:37
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
I have the same concern as you have all along. The problem is many retail investors or so-called traders who trade on fundamental news refuse to believe in the technicals of it.
|
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
singaporegal
Supreme |
26-Aug-2008 11:15
Yells: "Female TA nut" |
||||||||||||||||||||||
x 0
x 0 Alert Admin |
Study the volume of Biosensors and you'll see that it is inconsistent. Sometimes very high and sometimes very low. This fact, coupled by its penny stock status, makes it a very risky counter for retail players. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
bengster68
Master |
25-Aug-2008 16:00
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
There was some kind of confusion because BIG did not put up SGX announcement for thye benefit of retail shareholders. After listening to their webcast and calling BIG's office reception, I discovered interim 9 months LEADERS results will be discussed at ESC2008. 12 months LEADERS results will be discussed at TCT2008. Most likely by 04/09/08 BIG will let us know the 9 months LEADERS results. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
ironside
Member |
25-Aug-2008 15:07
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
Hi Bengster, earlier you have posted : BIOSENSORS WILL BE PARTICIPATING IN EUROPEAN SOCIETY OF CARDIOLOGY CONFERENCE ESC2008 FROM 30/08 TO 03/09/2008 IN GERMANY. ESC IS THE LARGEST CARDIOLOGY CONFERENCE IN EUROPE. BIOSENSORS WILL BE THE LIMELIGHT AT ESC2008. I have noted that the LEADERS result will be announced in Mid-Oct at TCT 08 in USA. The LEADERS trial result will be announced in early Sept. 08 in Germany or in mid Oct in the US ? | ||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
bengster68
Master |
25-Aug-2008 12:36
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
This is the article. Good stuff! Check out the red highlighted data. At 28 days, the BMS is completely healed but look at the healing progress of Cypher and Taxus. Very jialat. That is why late-thrombosis cases from Cypher and Taxus is also jialat. Comparing BMS VS Endeavor and Xience, BMS healing is still much better. Biomatrix is a BMS at the endothelisation healing stent surface. Start to appreciate more of BIG's DES technology better now? |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
bengster68
Master |
25-Aug-2008 12:26
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
Both Cypher and Biomatrix are using Stainless Steel BMS. As i mentioned before, Stainless Steel material seems rather outdated compared to newer metal alloys like Chromium Cobalt but the major plus point of Stainless Steel is the recoil factor after balloon expansion. Chromium Cobalt has a recoil of around 9% while Stainless Steel has very minimal stent recoil. So my guess is the "vessel constriction" when performing "Altria Pacing" like fast walking exercises which increases the heart rate and blood flow could be due to the endothelisation healing progress. This healing progress is on the stent surface where the blood is flowing inside the vessel. If the endothelisation healing is poor, we will see incomplete healing (some covered with healthy regrowth cells, some stent surface still exposed). This effectively causes uneven and rippled surface where the blood is flowing. Hence, there will be more difficulty and "constriction" for blood flow as compared to nice and smooth endothelisation healing totally covering the stent surface. I remember Mr Investor posted an article by Dr Renu comparing endothelisation in animal models whereby she di-sected the vessel between various DESs and BMS. She discovered BMS has a much much higher healing progress compared to DESs and Cypher and Taxus has the worst endothelisation healing. Biomatrix is essentially a BMS on the non-abumenal surface are which endothelisation healing occurs. Endothelisation healing has high corelation to late-thrombosis blood clot cases. That means the better the endothelisation, the lesser chance of late thrombosis cases. That is why i have highlighted earlier that BIG's manufacturing process using direct precision coating is a very good manufacturing technology. All other DESs uses spraying method for drug coating manufacturing process and particles of anti-restentosis drug may actually land on non-abumenal surface which will affect endothelisation healing. BIG is not only top class in DES technology and also top class in DES manufacturing method. |
||||||||||||||||||||||
Useful To Me Not Useful To Me | |||||||||||||||||||||||
investor
Senior |
25-Aug-2008 11:07
|
||||||||||||||||||||||
x 0
x 0 Alert Admin |
The Nobori Core Trial against Cypher was notable for a sub-study, where they did 'Atrial Pacing'. My understanding of 'Atrial Pacing' is that they monitor the stented vessel constriction, while subjecting the patient to increasing heart rate excercise. In this excercise, there was vessel constriction for the Cypher DES, ie the vessel seems to narrow, while the Bio-matrix stented vessel appears to be normal. This is suppose to imply that there is good endothelialisation for the Bio-matrix, such that the stented appears to be working normally, even under excercise, while there might be something in the cyper stented vessel that cause the blood vessel to constrict (probably inflammation, caused by incomplete endothelialisation). This is my understanding of the 'Atrial Pacing' concept - If there is anyone who knows about the topic, pleae correct me. Not a call to buy/Sell. | ||||||||||||||||||||||